
RE: | Letter Agreement Regarding Connection of Kentor, Carpenter, Shipman and Beazer Well Pads to Jupiter Gathering System |
a. | As of the date hereof, Rice Drilling B LLC, a Delaware limited liability company (“RDB”), shall be joined to the Agreement as a “Producer” (and, accordingly, a “Shipper”) and deemed a “Producer” (and, accordingly, a “Shipper”) under and subject to the Agreement for all purposes, entitled to all rights and benefits, and responsible for all obligations and liabilities, as “Producer” (and accordingly, as “Shipper”) arising pursuant to the Agreement, but insofar and only to the extent that the same arise out of, relate to, or are associated with RDB’s ownership, operation, or production of Gas delivered to the following Receipt Points: Beazer, Carpenter, Shipman, and Kentor. |
b. | Exhibit A attached to the Agreement is hereby deleted in its entirety and replaced with the revised Exhibit A attached hereto as Attachment 1. |
c. | Section II (Table of Incremental Capital Fees) of Exhibit B-2 attached to the Agreement is hereby deleted in its entirety and replaced with the revised Section II (Table of Incremental Capital Fees) attached hereto as Attachment 2. In accordance with Section 4.2(b) of the Agreement, the Parties have agreed to the Incremental Capital Projects in respect of the Receipt Points identified in Section II of Exhibit B-2. The Parties further agree that: |
i. | these Incremental Capital Projects shall not trigger an increase in the Compression MDQ or the Contract MDQ or an extension of any Term under the Agreement; |
ii. | with respect to the West Run – Hopewell Ridge Receipt Point, the Incremental Capital Fee shall be a negotiated volumetric rate of [***] (in lieu of a Monthly reservation rate) for all Gas delivered by Shipper and received by Gatherer at the West Run – Hopewell Ridge Receipt Point, and with respect to the remainder of the Receipt Points identified in Section II of Exhibit B-2, the Incremental Capital Fee shall be a negotiated volumetric rate of [***] (in lieu of a Monthly reservation rate) for all Gas delivered by Shipper and received by Gatherer at such Receipt Points; and all Receipt Points identified on Section II of Exhibit B-2 shall be disregarded for purposes of and not considered in calculating the Contract MDQ, Compression MDQ or the Overrun Fees under the Agreement; |
iii. | the Incremental Capital Fee shall apply only to Gas delivered to the Receipt Points identified in Section II of Exhibit B-2 beginning on the applicable In-Service Date for each such Receipt Point as set forth in Section II of Exhibit B-2, and thereafter shall apply to such Gas consistent with the Applicable Expansion Term provisions. |
iv. | Except for the West Run – Hopewell Ridge Receipt Point, Gas delivered to the Receipt Points identified in Section II of Exhibit B-2 shall be nominated by Shipper to Delivery Point JPTR-PAPER identified in Exhibit A. Nominations on Equitrans associated with the JPTR-PAPER Delivery Point and physical deliveries shall be reconciled on a monthly basis and any resulting imbalance shall be resolved by Shipper in the subsequent accounting month. No Gas delivered to Receipt Points other than those identified in Section II of Exhibit B-2 (not including the West Run – Hopewell Ridge Receipt Point) shall be nominated by Shipper to Delivery Point JPTR-PAPER. |
v. | Shipper shall not install wellhead or other compression upstream of the West Run – Hopewell Ridge Receipt Point without prior written consent from Gatherer. |
d. | In Section III (Site Specific Data and Facility Responsibility Matrix) of Exhibit F attached to the Agreement: |
i. | the pages including Section III.A.1 (Receipt Point Interconnect Data) are hereby deleted in their entirety and replaced with the revised pages including Section III.A.1 (Receipt Point Interconnect Data) attached hereto as Attachment 3; and |
ii. | Section III.A.2 (Responsibility for Interconnect Facility Equipment) is hereby amended to include the additional Interconnect Facilities responsibilities tables for the meters identified as set forth below, which tables (1) establish the design, construction, operation, maintenance and cost responsibility for each such meter and (2) are attached hereto as Attachment 3. |
EQT PRODUCTION COMPANY | EQM GATHERING OPCO, LLC |
By: ______________________________ | By: ______________________________ |
Name: ______________________________ | Name: ______________________________ |
Title: ______________________________ | Title: ______________________________ |
EQT ENERGY, LLC | RICE DRILLING B LLC |
By: ______________________________ | By: ______________________________ |
Name: ______________________________ | Name: ______________________________ |
Title: ______________________________ | Title: ______________________________ |
Receipt Point(s) | Receipt Point MDQ MMcf/Day | Zone | Zone MDQ MMcf/Day |
West Run | 80 | Zone 1 | 300 |
Koloski | 90 | Zone 1 | 300 |
Green Hill | 80 | Zone 1 | 300 |
Pierce | 100 | Zone 1 | 300 |
Walker B | 30 | Zone 1 | 300 |
Moore | 40 | Zone 1 | 300 |
Phillips | 30 | Zone 1 | 300 |
Scotts Run | 30 | Zone 1 | 300 |
Patterson Creek | 60 | Zone 1 | 300 |
Carpenter | 115 | Zone 1 | 300 |
Kentor | 5 | Zone 1 | 300 |
Moninger | 200 | Zone 2 | 370 |
Cooper | 140 | Zone 2 | 370 |
Big Sky | 75 | Zone 2 | 370 |
Harris | 45 | Zone 2 | 370 |
Amity | 15 | Zone 2 | 370 |
Harden Farm | 110 | Zone 2 | 370 |
Connors | 65 | Zone 2 | 370 |
Pettit | 65 | Zone 2 | 370 |
Hughes | 55 | Zone 2 | 370 |
Roberts | 9 | Zone 2 | 370 |
Harden | 25 | Zone 2 | 370 |
Shipman | 37.5 | Zone 2 | 370 |
J&J | 37.5 | Zone 2 | 370 |
Lacko | 150 | Zone 3 | 370 |
Hildebrand | 35 | Zone 3 | 370 |
Pyles | 40 | Zone 3 | 370 |
Beazer | 50 | Zone 3 | 370 |
Yabolnski | 70 | Zone 3 | 370 |
Minor | 60 | Zone 3 | 370 |
Nicoloff | 30 | Zone 3 | 370 |
McMillan | 20 | Zone 3 | 370 |
Robinson | 20 | Zone 3 | 370 |
Thompson | 25 | Zone 3 | 370 |
Thistlewaite | 2 | Zone 3 | 370 |
Alpha | 80 | Zone 3 | 370 |
Strope | 100 | Zone 3 | 370 |
Delivery Point(s) | Location |
Ingram | Equitrans H-109 |
Amity | Equitrans H-125 |
Jupiter | Equitrans H-148 |
Callisto | Equitrans H-160 |
Hopewell Ridge | Equitrans H-160 |
Pipers Ridge | Equitrans M-78 |
Europa | Equitrans H-165 |
Io | Equitrans H-148 and M-78 |
JPTR-PAPER | N/A |
Drip Liquids Delivery Point(s) | Location |
Not applicable | |
Contract MDQ: | [***] |
Compression MDQ: | [***] |
Incremental Capital Project | Contract MDQ | Incremental Capital Fee | In-Service Date | Applicable Expansion Term |
Carpenter | [***] | [***] | [***] | Until [***], and thereafter until terminated by either Party on the last Day of a Month by delivering written notice to the other Party at least thirty (30) Days prior to the date of termination. |
Kentor | [***] | [***] | [***] | Until [***], and thereafter until terminated by either Party on the last Day of a Month by delivering written notice to the other Party at least thirty (30) Days prior to the date of termination. |
Shipman 1 | [***] | [***] | [***] | Until [***], and thereafter until terminated by either Party on the last Day of a Month by delivering written notice to the other Party at least thirty (30) Days prior to the date of termination. |
Beazer 2 | [***] | [***] | [***] | Until [***], and thereafter until terminated by either Party on the last Day of a Month by delivering written notice to the other Party at least thirty (30) Days prior to the date of termination. |
West Run – Hopewell Ridge Receipt Point | [***] | [***] | [***] | Until terminated by either Party on the last Day of a Month by delivering written notice to the other Party at least thirty (30) Days prior to the date of termination. |
1. | Subject, in all respects, to Section 4 of that certain letter agreement dated as of March 1, 2019, by and among RM Partners LP, Rice Drilling B LLC, EQM Gathering OPCO, LLC, and Equitrans, L.P. (the “Letter Agreement”). |
A. | In addition to the minimum design specification and operating parameters set forth in the Engineering and Technical Design Standards, the following specifications shall be followed: |
1. | Receipt Point Interconnect Data: The table below provides for the list of meters covered under this Agreement which may be updated from time to time in accordance with the terms and conditions of this Agreement. Each meter in the Receipt Point Interconnect table shall conform to the specifications listed in the table applicable to such meter under Section III(A)(2). |
Meter ID | Meter Name | GPS Coordinates | MAOP | MinDQ* (Mcf / Day) | MaxDQ (Mcf / Day) |
17019 | Cooper B | 39.95597, -80.26908 | 720 | 1,220 | 78,500 |
11798 | Roberts 1 | 39.94097, -80.326422 | 720 | 320 | 19,600 |
17018 | Roberts 2 | 39.94097, -80.25422 | 720 | 320 | 19,600 |
11796 | McMillen | 39.9836, -80.1209 | 720 | 710 | 45,900 |
M5256116 | McMillen 2 MM - 1 | 39.98455, -80.11803 | 1400 | 2,100 | 51,433 |
M5256117 | McMillen 2 MM - 2 | 39.98455, -80.11803 | 1400 | 2,100 | 51,433 |
M5256118 | McMillen 2 MM - 3 | 39.98455, -80.11803 | 1400 | 2,100 | 51,433 |
17042 | Pyles 1 | 39.969918, -80.110996 | 1,440 | 1,670 | 78,500 |
M5224755 | Pyles 2 | 39.96643, -80.1116 | 1440 | 1,227 | 64,353 |
17035 | Hildebrand | 39.974133, -80.096991 | 720 | 650 | 45,900 |
17022 | Robison 1 | 39.979817, -80.072114 | 720 | 680 | 45,900 |
18156 | Robison 2 | 39.97799, -80.07021 | 720 | 720 | 45,900 |
17043 | Thompson 1 | 39.948602, -80.096748 | 720 | 680 | 45,900 |
17115 | Thompson 2 | 39.948602, -80.096748 | 720 | 680 | 45,900 |
11797 | Thistlewaite | 39.96395, -80.100731 | 720 | 320 | 19,600 |
17044 | Conner 1 | 39.946228, -80.240644 | 720 | 680 | 45,900 |
5100003 | Conner 2 | 39.946228, -80.240644 | 720 | 680 | 45,900 |
17037 | Phillips | 39.933614, -80.293665 | 1,400 | 1,150 | 115,300 |
18155 | Walker B | 39.934471, -80.318565 | 1,400 | 1,600 | 67,500 |
Meter ID | Meter Name | GPS Coordinates | MAOP | MinDQ* (Mcf / Day) | MaxDQ (Mcf / Day) |
5100014 | Scott’s Run 1 | 39.93239, -80.32793 | 1,400 | 2,700 | 115,300 |
5100015 | Scott’s Run 2 | 39.93239, -80.32793 | 1,400 | 2,700 | 115,300 |
M5225755 | Scott's Run 3 | 39.93237, -80.32812 | 1,400 | 1,227 | 64,353 |
5100065 | Moore MM B Run | 39.92772, -80.33715 | 1,400 | 2,700 | 115,300 |
M5277181 | Moore MM Run 2 | 39.92763, -80.33740 | 1440 | 1,150 | 28,800 |
5100039 | West Run (NIJUS25) | 39.913752, -80.303533 | 1,400 | 2,700 | 115,300 |
5100053 | West Run – Hopewell Ridge | 39.91312, -80.30316 | 1,400 | 2,511 | 87,994 |
5100055 | Patterson 1 | 39.936506 , -80.310759 | 1,400 | 2,700 | 115,300 |
5100063 | Patterson 2 | 39.936506 , -80.310759 | 1,400 | 2,700 | 115,300 |
5100057 | Nicoloff 1 | 39.954037, -80.065039 | 720 | 720 | 45,900 |
M5224083 | Nicoloff 2 | 39.954037, -80.065039 | 720 | 1,227 | 44,838 |
5100019 | Pierce 2 | 39.90734, -80.28209 | 720 | 2,630 | 78,500 |
5100064 | Pierce 3 | 39.90734, -80.28209 | 720 | 2,630 | 45,900 |
M5298308 | Pierce MM D Run | 39.90734, -80.28209 | 720 | 2,630 | 78,500 |
M5213961 | Big Sky 1 | 39.99805556,-80.20277 | 720 | 1,750 | 78,500 |
M5213962 | Big Sky 2 | 39.99805556, -80.20277 | 720 | 1,750 | 78,500 |
M5213963 | Big Sky 3 | 39.99805556, -80.20277 | 720 | 1,030 | 45,900 |
M5220213 | Petit 1 | 39.94523, -80.23994 | 720 | 1,227 | 44,838 |
M5220220 | Petit 2 | 39.94523, -80.23994 | 720 | 1,227 | 44,838 |
M5220221 | Petit 3 | 39.94523, -80.23994 | 720 | 726 | 26,240 |
M5248813 | Petit 4 | 39.94684, -80.24028 | 1,440 | 1,227 | 64,353 |
M5248814 | Petit 5 | 39.94684, -80.24028 | 1,440 | 1,227 | 64,353 |
M5248816 | Petit 6 | 39.94684, -80.24028 | 1,440 | 1,227 | 64,353 |
M5254623 | Petit 7 | 39.94684, -80.24028 | 1,440 | 1,227 | 64,353 |
M5224627 | Alpha 1 | 39.960097, -80.130604 | 720 | 1,227 | 44,838 |
M5224714 | Alpha 2 | 39.960097, -80.130604 | 720 | 1,227 | 44,838 |
M5274373 | Alpha 3 | 39.960097, -80.130604 | 720 | 1,950 | 35,500 |
M5234610 | Moninger Run 1 | 39.99511, -80.20636 | 1,440 | 1,227 | 64,353 |
Meter ID | Meter Name | GPS Coordinates | MAOP | MinDQ* (Mcf / Day) | MaxDQ (Mcf / Day) |
M5234612 | Moninger Run 2 | 39.99511, -80.20636 | 1,440 | 1,227 | 64,353 |
M5234613 | Moninger Run 3 | 39.99511, -80.20636 | 1,440 | 1,227 | 64,353 |
M5235813 | Moninger Run 4 | 39.99511, -80.20636 | 1,440 | 1,227 | 64,353 |
M5234486 | Koloski Run 1 | 39.95875, -80.31068 | 1,440 | 1,227 | 64,353 |
M5234487 | Koloski Run 2 | 39.95875, -80.31068 | 1,440 | 1,227 | 64,353 |
M5234488 | Koloski Run 3 | 39.95875, -80.31068 | 1,440 | 1,227 | 64,353 |
17020 | Iames | 40.0308, -80.15266 | 720 | 726 | 37,660 |
M5219031 | Shipman 1 | 39.991551, -80.194235 | 720 | 726 | 37,660 |
M5219033 | Shipman 2 | 39.991551, -80.194235 | 720 | 1,227 | 64,353 |
M5258883 | Shipman Gathering MM - Run 3 | 39.991551, -80.194235 | 720 | 1,950 | 35,500 |
33297 | Ingram 590004 | 39.93929, -80.26466 | 720 | 356 | 16,118 |
33341 | ROG46H1 | 39.94097, -80.26422 | 720 | 356 | 16,118 |
M5210064 | Lacko 1 | 39.968683, -80.150911 | 720 | 1,227 | 64,353 |
M5210065 | Lacko 2 | 39.968683, -80.150911 | 720 | 1,227 | 64,353 |
M5210066 | Lacko 3 | 39.968683, -80.150911 | 720 | 1,227 | 64,353 |
M5234259 | Yablonski 1 | 39.99347, -80.06271 | 1440 | 1,227 | 64,353 |
M5234260 | Yablonski 2 | 39.99347, -80.06271 | 1440 | 1,227 | 64,353 |
M5226733 | Beazer 1 | 39.92417, -80.10866 | 1440 | 1,227 | 64,353 |
M5226735 | Beazer 2 | 39.92417, -80.10866 | 1440 | 1,227 | 64,353 |
M5249530 | Beazer 3 | 39.92417, -80.10866 | 1440 | 1,556 | 57,163 |
M5238116 | J & J | 39.99807, -80.20293 | 1440 | 1,556 | 57,163 |
M5238117 | J & J | 39.99807, -80.20293 | 1440 | 1,556 | 57,163 |
M5248049 | J & J | 39.99807, -80.20293 | 1440 | 1,556 | 57,163 |
M5241305 | Harden Farm 1 | 39.939969, -80.264877 | 1440 | 1,556 | 57,163 |
M5241307 | Harden Farm 2 | 39.939969, -80.264877 | 1440 | 1,556 | 57,163 |
M5241308 | Harden Farm 3 | 39.939969, -80.264877 | 1440 | 1,556 | 57,163 |
Meter ID | Meter Name | GPS Coordinates | MAOP | MinDQ* (Mcf / Day) | MaxDQ (Mcf / Day) |
M5274165 | Green Hill - Meter 1 | 39.89708, -80.31778 | 1400 | 2,100 | 31,750 |
M5274166 | Green Hill - Meter 2 | 39.89708, -80.31778 | 1400 | 2,100 | 31,750 |
M5274167 | Green Hill - Meter 3 | 39.89708, -80.31778 | 1400 | 2,100 | 31,750 |
M5272524 | Harris | 39.95349, -80.19008 | 720 | 1,800 | 49,000 |
M5291357 | Harris Run B | 39.95349, -80.19008 | 720 | 1,800 | 49,000 |
M5283458 | EPC Carpenter MM Run A | 39.8864, -80.3359 | 1400 | 1,800 | 49,000 |
M5283463 | EPC Carpenter MM Run B | 39.8864, -80.3359 | 1400 | 1,800 | 49,000 |
M5283464 | EPC Carpenter MM Run C | 39.8864, -80.3359 | 1400 | 1,800 | 49,000 |
M5344758 | Kentor | 39.877229, -80.307607 | 1400 | 200 | 6,500 |
2. | Responsibility for Interconnect Facility Equipment. Each of the following tables establish, for the meter specified in the cell located in the first row of the first column of such table (or, if no meter is specified in such cell, then for each meter not specified in any of the other tables included below) the design, construction, operation, maintenance and cost responsibility for certain aspects of the Interconnect Facilities. All of the following design responsibilities designated as Producer’s responsibility shall be incorporated into the design and construction of the Interconnect Facilities. |
Pierce 2, 5100019 Pierce 3, 5100064 Pierce MM D Run, M5298308 STATION EQUIPMENT | REQUIRED | DESIGN | INSTALL | OWNERSHIP | OPERATE | MAINTAIN | SPECIAL PROVISIONS/ EQUIPMENT SPECS. |
PIPING | |||||||
Pipeline-Tap & Valve | Yes | Gatherer | Gatherer | Gatherer | Gatherer | Gatherer | 12” Tee |
Inlet & Station Piping | Yes | Producer | Producer | Producer | Producer | Producer | |
Outlet & Station Piping | Yes | Gatherer | Producer | Producer | Gatherer | Producer | 12” |
Test Station - inlet piping | Yes | Producer | Producer | Producer | Producer | Producer | |
Test Station - outlet piping | Yes | Gatherer | Gatherer | Gatherer | Gatherer | Gatherer | |
Corrosion coupon | Yes | Gatherer | Gatherer | Gatherer | Gatherer | Gatherer | |
GAS CONDITIONING | |||||||
Filter Separator | Yes | Gatherer | Producer | Producer | Producer | Producer | Shawndra Filter |
Liquid Level Shutoff | No | 16” Barrel | |||||
MEASUREMENT | |||||||
Meter & Meter Runs | Yes | Gatherer | Producer | Producer | Gatherer | Producer | (2) 8” Orifice, (1) 6” Orifice |
Meter & Flow Control Risers, Valves, etc… | Yes | Gatherer | Producer | Producer | Gatherer | Producer | |
Electronic Measurement & Telecom Hardware | Yes | Gatherer | Producer | Producer | Gatherer | Producer | Eagle/1 RTU (ea meter) and Eagle /5 RTU per interconnect |
GAS QUALITY | |||||||
Chromatograph | No | ||||||
Continuous Sampler | No | ||||||
H2O Dew Point Analyzer | No | ||||||
Oxygen Analyzer | No | Gatherer | Producer | Producer | Gatherer | Producer | |
H2S Monitor | No | Gatherer | Producer | Producer | Gatherer | Producer | |
PRESSURE / FLOW CONTROL | |||||||
Primary Pressure Control | Yes | Gatherer | Producer | Producer | Gatherer | Producer | 2X 6” CV/OPP + 1X4” CV/OPP |
Overpressure Device | Yes | Gatherer | Producer | Producer | Gatherer | Producer | 2X 6” OPP + 1X4” OPP |
Station Isolation Valve | Yes | Gatherer | Producer | Producer | Gatherer | Producer | 12” |
Flow Control Valve | Yes | Gatherer | Producer | Producer | Gatherer | Producer | 2X 6” + 1X4” CV (same devices as the top) |
Heat | No | Gatherer | Producer | Producer | Producer | Producer | |
Check Valve | Yes | Gatherer | Producer | Producer | Producer | Producer | 2 X 8” + 1X6” |
ODORIZATION | |||||||
Odorizer & Controls | No | Gatherer | Producer | Producer | Gatherer | Producer | |
MISCELLANEOUS | |||||||
Communication service | Yes | Gatherer | Gatherer | Gatherer | Gatherer | Gatherer | EQT Spec |
Electrical Service | Yes | Gatherer | Producer | Producer | Gatherer | Producer | Solar |
Building - Gas Chromatograph | No | ||||||
Building - Odorizer | No | Gatherer | Producer | Producer | Gatherer | Producer | |
Fence/Vehicle Barrier/Signage | Yes | Gatherer | Producer | Producer | Gatherer | Producer | |
Air Permit | TBD | Producer | Producer | Producer | Producer | Producer | |
EPC Carpenter MM Run A, M5283458 EPC Carpenter MM Run B, M5283463 EPC Carpenter MM Run C, M5283464 STATION EQUIPMENT | REQUIRED | DESIGN SPECIFICATIONS | INSTALL | OWNERSHIP | OPERATE | MAINTAIN |
PIPING | ||||||
Company Pipeline Tap & Valve | Yes | Company | Company | Company | Company | Company |
Inlet Piping | Yes | Customer | Customer | Customer | Customer | Customer |
Station & Outlet Piping | Yes | Company | Customer | Customer | Company | Customer |
Cathodic Protection - Inlet, Station, & Outlet Piping | Yes | Customer | Customer | Customer | Customer | Customer |
Cathodic Protection - Company Tap & Valve | Yes | Company | Company | Company | Company | Company |
GAS CONDITIONING | ||||||
Filter Separator | Yes | Company | Customer | Customer | Customer | Customer |
Particulate Filter | No | |||||
Liquid Level Shutoff | No | |||||
MEASUREMENT | ||||||
Meter & Meter Runs | Yes | Company | Customer | Customer | Company | Customer |
Meter & Flow Control Risers, Valves, etc… | Yes | Company | Customer | Customer | Company | Customer |
Electronic Measurement & Telecomm Hardware | Yes | Company | Customer | Customer | Company | Customer |
GAS QUALITY | ||||||
Chromatograph | No | |||||
Moisture Analyzer | No | |||||
Oxygen Analyzer | No | |||||
Hydrogen Sulfide Analyzer | No | |||||
PRESSURE / FLOW CONTROL | ||||||
Overpressure Protection Device | Yes | Company | Customer | Customer | Company | Customer |
Primary Pressure Control | No | |||||
Flow Control | No | |||||
Remote Shutoff Valve | No | |||||
Heater | No | |||||
Check Valve | Yes | Company | Customer | Customer | Company | Customer |
ODORIZATION | ||||||
Odorizer & Controls | No | |||||
MISCELLANEOUS | ||||||
Communication Service(s) | Yes | Company | Customer | Customer | Company | Customer |
Electrical Service | Yes | Company | Customer | Customer | Company | Customer |
Building - Gas Chromatograph | No | |||||
Building / Enclosure - Odorizer | No | |||||
Fence/Vehicle Barrier/Signage | Yes | Company | Customer | Customer | Company | Customer |
Kentor, M5344758 STATION EQUIPMENT | REQUIRED | DESIGN SPECIFICATIONS | INSTALL | OWNERSHIP | OPERATE | MAINTAIN |
PIPING | ||||||
Company Pipeline Tap & Valve | Yes | Company | Company | Company | Company | Company |
Inlet Piping | Yes | Customer | Customer | Customer | Customer | Customer |
Station & Outlet Piping | Yes | Company | Company | Company | Company | Company |
Cathodic Protection - Station, & Outlet Piping | Yes | Company | Company | Company | Company | Company |
Cathodic Protection - Company Tap & Valve | Yes | Company | Company | Company | Company | Company |
GAS CONDITIONING | ||||||
Filter Separator | Yes | Company | Company | Company | Company | Company |
Particulate Filter | No | |||||
Liquid Level Shutoff | No | |||||
MEASUREMENT | ||||||
Meter & Meter Runs | Yes | Company | Company | Company | Company | Company |
Meter & Flow Control Risers, Valves, etc… | Yes | Company | Company | Company | Company | Company |
Electronic Measurement & Telecomm Hardware | Yes | Company | Company | Company | Company | Company |
GAS QUALITY | ||||||
Chromatograph | No | |||||
Moisture Analyzer | No | |||||
Oxygen Analyzer | No | |||||
Hydrogen Sulfide Analyzer | No | |||||
PRESSURE / FLOW CONTROL | ||||||
Overpressure Protection Device | Yes | Company | Company | Company | Company | Company |
Primary Pressure Control | No | |||||
Flow Control | No | |||||
Remote Shutoff Valve | Yes | Company | Company | Company | Company | Company |
Heater | No | |||||
Check Valve | Yes | Company | Company | Company | Company | Company |
ODORIZATION | ||||||
Odorizer & Controls | No | |||||
MISCELLANEOUS | ||||||
Communication Service(s) | Yes | Company | Company | Company | Company | Company |
Electrical Service | Yes | Company | Company | Company | Company | Company |
Building - Gas Chromatograph | No | |||||
Building / Enclosure - Odorizer | No | |||||
Fence/Vehicle Barrier/Signage | Yes | Company | Company | Company | Company | Company |